Since 1948
Manufacturers of Residential,
Commercial and Industrial Doors
• Tel.: 1.800.465.1925 / 514.453.5120 • Fax: 514.453.1518  •  E-mail: info@doriondoors.com
2987 Boul. Perrot, Ile Perrot (Quebec) Canada J7V 8P4
 
 Corporate Profile Français  Español 
garage doors, sectionnal doors, multi-blades doors, sliding garage doors. manufacturer for standard, commercial and industrial garage doors
ACCESSORIES AND CONTROLS
FOR ELECTRIC OPERATORS

 
 
1 - THREE BUTTON CONTROL STATION (OPEN/CLOSE/STOP) IN EEMAC TYPE 1 ENCLOSURE.
Standard equipement with all operators except EEMAC type 4 & 12 and explosion proof operators.

2 - EXTERIOR WEATHERPROOF THREE BUTTON CONTROL STATION (OPEN/CLOSE/STOP).
Suitable for interior or exterior applications. Standard equipement with all EEMAC type 4 & 12 operators.

3 - WEATHERPROOF THREE BUTTON CONTROL STATION (OPEN/CLOSE/STOP) EEMAC TYPE 4 WITH KEY LOCK-OUT.
When the key is turned to the lock position, pushbuttons are inoperative. Interior or exterior applications.

4 - WEATHERPROOF THREE BUTTON CONTROL STATION (OPEN/CLOSE/STOP) EEMAC TYPE 4 WITH PILOT LIGHT.
Suitable for interior or exterior applications.

5 - WEATHERPROOF THREE BUTTON CONTROL STATION (OPEN/CLOSE/STOP) EEMAC TYPE 4 WITH KEY LOCK-OUT & PILOT LIGHT.
Suitable for interior or exterior applications.

6 - EXPLOSION PROOF THREE BUTTON CONTROL STATION (OPEN/CLOSE/STOP) EEMAC TYPE 7 & 9.
Standard equipement with all EEMAC type 7 & 9 explosion proof operators.

7 - HEAVY DUTY PULL CORD SWITCH.
Used to activate operator to open or close from driver's seat. Suitable for interior and exterior use.

8 - WEATHERPROOF KEY SWITCHES.
Momentary contact will open and close the door. Can be wall or post mounted for interior or exterior use.

9 - SINGLE AND DUAL TIMERS.
These timers automatically close the door after a preset time and control warning signal lights. Single timer is adjustable from 0 to 90 seconds. Dual mode is adjustable from 0 to 180 seconds an can be wired to control red and green warning signal lights to desired functions. Both timers will reset to 0 second each time an opening control is activated during the timer cycle.

10- MAGNETIC VEHICULE LOOP DETECTORS (SARASOTA 515B).
These are completely transistorized electronic units with dual function and a continuous automatic self tuning feature. They are used for detecting the presence or passage of a vehicule over wire loops embedded in the roadway surface. When a vehicule passes over the loop, the unit will open the door. If, during the downward travel of the door, a vehicule passes over the loop, the door will reverse to the open position.
The dual function permits two loops to be used. When the exterior loop is not required (overnight), one need only to turn a switch and only the interior loop will function.

 
 
11 - PHOTO-ELECTRIC CONTROLS (OPCON)
These can be used as opening and reversing devices. An infra red light emitted from the control to a reflector and back. When this beam is broken, the door will open. If, during the downward travel of the door a vehicule breaks the beam, the door will reverse to its fully opened position.

12 - RADIO CONTROLS.
Residential: Used to open and close a door from a distance (ex; from your car). Available with one or more transmitters.
Commercial: With three positions (Open/close/stop) Transmitters to control from ONE to TWENTY SEVEN doors with positive action sliding switch.

14 - ELECTROMECHANICAL SAFETY EDGE.
Installed on the bottom section of the door. When it encounters an obstruction, the reversing switch is activated and the door reverses to its fully opened position or it can be wired to stop.

15 - ELECTROPNEUMATIC SWITCH.
Electropneumatic switch with 305 mm long clear hose to insert into the AGDS safety edge.

16 - REELITES.
Offered as an option to coil cord. It keeps the cord out of the way to prevent damage. Shown is a two conductors reelite with 6100mm cord. Three conductors reelite with 9150mm cord.

17 - AGDS SAFETY EDGE.
Santoprene rubber closed at both ends for the air enclosure. Installed on the bottom section of the door. When it encounters an obstruction, the reversing switch is activated and the door reverses to its fully opened position or it can be wired to stop.
Includes item 15.

18 - TRAFFIC LIGHTS.
Available as dual (red & green) or single (red or green) set. They are enclosed in a weatherproof housing and have 203mm diameter lenses. Galvanised mounting bracelets are included. Flashing signal is optional. The required voltage is 110 V.A.C. Also available in 240 V.A.C., one phase and three phase operators, at extra costs. Standard operation: red light is on when the door is moving up or down; the green light is on when the door is opened; both lights are closed when door is closed.

 
 
19 - CHAIN SPREADER.
For use on jackshaft type operators. It is designed to be installed between the operator drive shaft to keep the drive chain tight.

20 - 1.5 SECOND TIME DELAY RELAY
Used in conjunction with instant reverse wiring. It prevents harsh jolting of the door and cables during reversing cycle. (optional at an extra cost).

21 - 1 AMP. RESET.
Used in lieu of fuse. Installed with reset button protruding from control box which allows customers to reset the unit themselves. It eliminates problems caused by blowing fuses due to shorts during hook-ups (optional at an extra cost).

22 - HEATER PACKAGE.
Consist of heater strip 150W standard, (250W or 500W optional at an extra cost) thermostat and tranformer (not required on single phase units).

23 - KEY POST STAND.
Heavy duty stand: can be used to house key switch (a) or card reader (b).

24 - PD20 VEHICULE DETECTOR.
Replaces loops either temporarily or permanently. Easy to install or repair. No seasonal tuning required. Detects smallest licensed vehicules.

25 - MAGNETIC HOLDERS: TYPE FS.
Continuously energized fail safe unit. Releases when there is an interruption of power supply. Available in 110 V.A.C., 24 V.A.C., 24 V.D.C. or 12 V.D.C.

26 - MAGNETIC HOLDERS: TYPE AR.
Releases when current is applied om signal from the detector or alarm system. Available with adjustable time delay only in 110 V.

27 - SMOKE DETECTORS: PHOTOELECTRIC TYPE.
Can be furnished with heat detector as well. Available for 115 volt service, U.L. listed.

28 - SMOKE DETECTORS: IONIZATION TYPE.
Available for 115 volt. Trim, compact, low profile design. U.L. listed.

 
Back

Copyright 2001, Portes Dorion Doors Inc. All Rights Reserved.
Site information and comments: info@uducat.com